COM-PAK SERIES
| FX, RX and X MODELS TO C, CE,CS, CB or CM | |
|---|---|
| IF YOU HAVE THIS… | REPLACE WITH ONE OF THESE OPTIONS |
| FX052 | CS052, CB132T, CE163T, CM202 |
| FX051, RX051, FX071 | CS051, *CE163T |
| FX072, RX072, X072 | CS072, *CE163T, CM162, CB132T |
| FX101, RX101, X101 | CS101, CE163T, CB103T |
| FX102, RX102, X102 | CS102, CE163T, CM162, CB103T |
| FX122, RX122, X122 | CS122, CE163T, CM202 |
| FX151, RX151, X151 | CS151 |
| FX152, RX152, X152 | CS152, CE163T, CM162 |
| FX242, RX242, FX202, RX202, X202, X222 | CS202, CE163T, CM202 |
| FX208, X208 | CS208, CE163T, CM208 |
Note: CB, CE and CM not approved for ceiling mount. CTT1 and CTT2 - optional thermostat kits for C, CS, and CM heaters, if needed. Specify knob color. CB and CE come with in-built thermostats. Note: *Check load on circuit breaker prior to installation. |
|
| LX, RLX AND L MODELS (TWIN) TO CT, CST | |
| LX242, RLX242 | Contact Cadet Technical Support for assistance. |
| L302, LX302, RLX302 | CST302 |
| L402, L452, LX402, RLX402, LX482, RLX482 | CST402 |
| LX408, RLX408, L408 | CST408 |
Some Com-Pak Twin heaters have both heatboxes labeled FX (single unit model number) behind one grill. You will need to order a single CST for these replacements, NOT two CS single heater units. CTT1 and CTT2 - optional thermostat kits if needed.Specify knob color. |
|
REGISTER SERIES
| ZA, RA, Z, ZM MODELS TO RM | |
|---|---|
| IF YOU HAVE THIS… | REPLACE WITH THIS |
| Z051, ZA051, ZA071 | RM151, CONVERTED TO 500 WATTS |
| RA051, RA071 | RM151, CONVERTED TO 500 WATTS |
| Z072, ZA072, ZA052 | RM162, CONVERTED TO 700 WATTS |
| RA052, RA072 | RM162, CONVERTED TO 700 WATTS |
| Z101, ZA101, RA101 | RM151, CONVERTED TO 1000 WATTS |
| Z102, ZA102, RA102 | RM162, CONVERTED TO 900 WATTS |
| ZA122, RA122 | RM162, CONVERTED TO 900 WATTS |
| Z151, ZM151 | RM151, NO CONVERSION NECESSARY |
| ZA151, RA151 | RM151, NO CONVERSION NECESSARY |
| Z152, ZA152, RA152, ZM162 | RM162, NO CONVERSION NECESSARY |
| Z202, ZA202, RA202, ZM202 | RM202, NO CONVERSION NECESSARY |
| ZA242, RA242 | RM202, NO CONVERSION NECESSARY |
| Z208, ZM208 | RM208, NO CONVERSION NECESSARY |
| ZA208, RA208 | RM208, NO CONVERSION NECESSARY |
| ZA248 | RM208, NO CONVERSION NECESSARY |
PERFECTOE SERIES
| TK AND RK MODELS TO UC | |
|---|---|
| IF YOU HAVE THIS… | REPLACE WITH THIS |
| TK051, TK071, RK071 | UC051 |
| TK072, RK072 | UC072 |
| TK101, RK101, TK151, RK151 | UC101 |
| TK102, RK102, TK152, RK152 | UC102 |
| TS MODELS TO UC | |
| TS752 | UC072, PLUS UCAB ADAPTER |
| TS101 | UC101, PLUS UCAB ADAPTER |
| TS102 | UC102, PLUS UCAB ADAPTER |
| TS152 | UC102, PLUS UCAB ADAPTER |
| TS202 | UC102, PLUS UCAB ADAPTER |
| TS203 MULTI-WATT | Contact Cadet Technical Support for assistance |
Note: Optional built-in thermostat kits: UCT1 or UCT2. Specify knob color. |
|
RB SERIES
| RB SERIES | |
|---|---|
| IF YOU HAVE THIS… | REPLACE WITH THIS |
| RB101 | RBF101 |
| RB121 | RBF101 |
NLW SERIES
| NLW SERIES | |
|---|---|
| IF YOU HAVE THIS… | REPLACE WITH THIS |
| LW202, NLW202A | NLW202TW |
| LW 302, NLW302A | NLW302TW |
| LW402, NLW402A | NLW402TW |
| LW 482, NLW452A | NLW452TW |
| NLW208A | NLW208TW |
| NLW308A | NLW308TW |
| NLW408A | NLW408TW |
| LW207, LW307, LW407, LW487 | NO CURRENT CROSS |
Note: Minor sheetrock work and new wall can required for LW replacements. |
|
SL SERIES
| SL SERIES | |
|---|---|
| IF YOU HAVE THIS… | REPLACE WITH THIS |
| SL101A | SL101TW |
| SL121A | SL101TW |
| SL151A | SL151TW |
| SL208A, SL208TW | SL252TW 1875W @208V |
| SL258A, SL258TW | SL302TW, 2250W @208V |
| SL308A, SL308TW | SL302TW, 2250W @208V |
| SL152A | SL152TW |
| SL192A | SL192TW |
| SL252A | SL252TW |
| SL302A | SL302TW |
| B MODELS TO SL | |
| IF YOU HAVE THIS… | REPLACE WITH ONE OF THESE OPTIONS |
| B252 WIRED FOR 1500 WATTS | SL152TW, C152T PLUS CAM ADAPTER |
| B252 WIRED FOR 2000 WATTS | SL192TW, C202T PLUS CAM ADAPTER |
| B252 WIRED FOR 2500 WATTS | SL252TW |
| Other wattages not listed above | Contact Cadet Technical Support for assistance |
Note: Minor sheetrock work and new wall can required. |
|
| ADVANTAGE MODELS TO C/CS or CE | |
|---|---|
| IF YOU HAVE THIS… | REPLACE WITH THIS |
| VC102T | CS102T or CE163T PLUS CAM ADAPTER |
| VC152T | CS152T or CE163T PLUS CAM ADAPTER |
| VC202T | CS202T or CE163T PLUS CAM ADAPTER |
Note: Minor sheetrock work and new wall can required. |
|
| FW AND RW MODELS TO C/CS | |
|---|---|
| IF YOU HAVE THIS… | REPLACE WITH THIS |
| FW751, RW751 | CS051, PLUS FWAP ADAPTER |
| FW052, RW052 | CS052, PLUS FWAP ADAPTER |
| FW752, RW752 | CS072, PLUS FWAP ADAPTER |
| FW101, RW101 | CS101, PLUS FWAP ADAPTER |
| FW121, RW121 | CS101, PLUS FWAP ADAPTER |
| FW102, RW102 | CS102, PLUS FWAP ADAPTER |
| FW122, RW122 | CS122, PLUS FWAP ADAPTER |
| FW151, RW151 | CS151, PLUS FWAP ADAPTER |
| FW152, RW152 | CS152, PLUS FWAP ADAPTER |
| FW202, RW202 | CS202, PLUS FWAP ADAPTER |
| FW252, RW252 | CS202, PLUS FWAP ADAPTER |
| FW302, RW302 | CS202, PLUS FWAP ADAPTER |
Note: CTT1 and CTT2 - optional built in thermostat kit if needed. Must order thermostat separate from heater and mount on adapter plate. Specify knob color. Optional grill available. Specify white or almond color. |
|